MRCOOL DIY 5th Gen Multi-Zone Submittal Data Sheets & Specifications

If you are looking for MRCOOL DIY 5th Generation Multi-Zone submittal data, electrical specifications, dimensions, piping requirements, performance data, or installation clearances, this guide brings the information together in one place.
The MRCOOL® DIY® 5th Generation Multi-Zone lineup includes five outdoor condenser sizes ranging from an 18,000 BTU 3-zone system through a 55,000 BTU 6-zone system.
This guide covers:
- DIY-MULTI3-18HP230D-O
- DIY-MULTI4-27HP230D-O
- DIY-MULTI5-36HP230D-O
- DIY-MULTI6-48HP230D-O
- DIY-MULTI6-55HP230D-O
Below, you can find model-specific information taken from the MRCOOL submittal data sheets, including cooling and heating performance, SEER2, electrical requirements, MCA and MOCP, refrigerant information, piping specifications, dimensions, weights, and installation-clearance information.
Important: Submittal data is model-specific. Always verify the model number on your equipment and consult the current MRCOOL installation documentation before installation or electrical work.
MRCOOL DIY 5th Gen Multi Zone 👉 Shop Now
MRCOOL DIY 5th Gen Multi Zone 👉 Bundle Builder
Mrcool DIY 5th Gen 👉 Installation and owner’s manual
MRCOOL DIY-MULTI3-18HP230D-O Submittal Data
The DIY-MULTI3-18HP230D-O is the 18K-class outdoor unit in the DIY Multi-Zone Series.

General & Outdoor Specifications
|
Specification |
DIY-MULTI3-18HP230D-O |
|
Compressor Type |
Twin-Rotary |
|
Compressor Model |
KTN150D30UFZA |
|
Refrigerant Type |
R454B |
|
Refrigerant Oil Charge |
450 mL |
|
Refrigerant Oil |
VG74 |
|
Outdoor Air Flow (Max) |
1765.8 CFM |
|
Outdoor Noise Level |
60 dBA |
|
Unit Dimensions |
35.04 x 13.46 x 26.5 in |
|
Unit Dimensions Metric |
890 x 342 x 673 mm |
|
Package Dimensions |
40.55 x 17.24 x 29.53 in |
|
Package Dimensions Metric |
1030 x 438 z 750 mm |
|
Net/Gross Weight |
101.63 / 109.57 lb |
|
Net/Gross Weight Metric |
46.1 / 49.7 kg |
Efficiency
|
Cooling |
Rating |
Heating |
Rating |
|
SEER2 |
23.9 |
HSPF2-4 |
10 |
|
EER2 |
13 |
COP |
3.8 |
Cooling Performance
Rated cooling capacity is 18,000 BTU/h.
Minimum/maximum cooling capacity: 5,400–23,400 BTU/h.
Moisture removal: 1.1 L/h.
Standard cooling operating range: -13°F to 122°F (-25°C to 50°C).
Cooling rating conditions shown on the submittal are indoor 80°F DB/67°F WB and outdoor 95°F DB/75°F WB.
Heating Performance
At 47°F, rated heating capacity is 18,000 BTU/h, with a minimum/maximum capacity of 5,700–21,000 BTU/h.
At 17°F, rated heating capacity is 13,400 BTU/h.
At 5°F, rated capacity is 13,300 BTU/h with a COP of 2.3. The listed 5°F maximum capacity is 13,300 BTU/h.
Standard heating operating range: -13°F to 75°F (-25°C to 24°C).
Electrical Specifications
|
Electrical Specification |
Value |
|
Power Supply |
208/230V, 60Hz, 1Ph |
|
System MCA |
16A |
|
Connection Wiring |
14# x 4 |
|
System MOCP |
20A |
|
Compressor RLA |
8.2A |
|
Outdoor Fan Motor RLA |
1A |
|
Outdoor Fan Motor |
80W |
|
System Power Input - Cooling |
1385W (400 - 1860W) |
|
System Power Input - Heating |
1390W (350-1800W) |
Piping & Refrigerant
The submittal lists three 1/4-inch liquid connections and three 3/8-inch gas connections.
Maximum piping length for all rooms is listed as 172.2 ft, with a maximum individual indoor-unit piping length of 73.8 ft.
Maximum height difference between indoor and outdoor equipment: 32.8 ft.
Refrigerant precharge: 61.73 oz / 1.75 kg.
Precharge length: 24.6 ft × 3.
Connection method: Quick Connect.
MRCOOL DIY-MULTI4-27HP230D-O Submittal Data
The DIY-MULTI4-27HP230D-O is the 27K-class DIY Multi-Zone outdoor condenser.

Outdoor Specifications
|
Specification |
Value |
|
Compressor Type |
Rotary |
|
Compressor Model |
KTM240D46UKT2 |
|
Refrigerant |
R454B |
|
Refrigerant Oil Charge |
620 mL |
|
Refrigerant Oil |
VG74 |
|
Maximum Outdoor Airflow |
2130.7 CFM |
|
Outdoor Noise Level |
61 dBA |
|
Dimensions |
37.24 x 16.14 x 31.89 in |
|
Dimensions Metric |
946 x 410 z 810 mm |
|
Package Dimensions |
42.91 x 19.69 x 34.84 in |
|
Net/Gross Weight |
140.21 / 151.02 lb |
|
Net/Gross Weight Metric |
63.6 / 68.5 kg |
Efficiency
SEER2: 23
EER2: 12
HSPF2-4: 9.5
COP: 3.4
Cooling Performance
Rated cooling capacity: 26,000 BTU/h.
Minimum/maximum cooling capacity: 7,200–32,000 BTU/h.
Moisture removal: 2 L/h.
Standard cooling operating range: -13°F to 122°F (-25°C to 50°C).
Heating Performance
Rated heating capacity at 47°F: 26,000 BTU/h.
Minimum/maximum capacity at 47°F: 8,400–29,000 BTU/h.
Rated capacity at 17°F: 16,200 BTU/h.
At 5°F, rated capacity is 18,200 BTU/h, with a listed COP of 2 and maximum capacity of 18,200 BTU/h.
Standard heating operating range: -13°F to 75°F (-25°C to 24°C).
Electrical Specifications
|
Electrical Specification |
Value |
|
Power Supply |
208/230V, 60Hz, 1Ph |
|
System MCA |
23A |
|
Connection Wiring |
14# x 4 |
|
System MOCP |
25A |
|
Compressor RLA |
12.1A |
|
Outdoor Fan Motor RLA |
1.2A |
|
Outdoor Fan Motor |
150W |
|
Cooling Power Input |
2167W (500 - 2780W) |
|
Heating Power Input |
2241W (500 - 2440W) |
Piping & Refrigerant
Four 1/4-inch liquid connections and four 3/8-inch gas connections are listed.
Maximum piping length for all rooms: 221.4 ft.
Maximum piping length for one indoor unit: 73.8 ft.
Maximum indoor/outdoor height difference: 32.8 ft.
Refrigerant precharge: 84.66 oz / 2.4 kg.
Precharge length: 24.6 ft × 4.
Connection method: Quick Connect.
MRCOOL DIY 5th Gen Multi Zone 👉 Shop Now
MRCOOL DIY 5th Gen Multi Zone 👉 Bundle Builder
Mrcool DIY 5th Gen 👉 Installation and owner’s manual
MRCOOL DIY-MULTI5-36HP230D-O Submittal Data
This is the correct DIY 5th Generation 36K-class / 5-zone condenser and replaces the Olympus information we previously encountered.

Outdoor Specifications
|
Specification |
Value |
|
Compressor Type |
Rotary |
|
Compressor Model |
KTF310D43UMT |
|
Refrigerant |
R454B |
|
Refrigerant Oil Charge |
1000 mL |
|
Refrigerant Oil |
VG74 |
|
Maximum Outdoor Airflow |
2148.4 CFM |
|
Outdoor Noise Level |
64 dBA |
|
Dimensions |
37.24 x16.14 x 31.89 in |
|
Dimensions Metric |
946 x 410 x 810 mm |
|
Package Dimensions |
42.91 x 19.69 x 34.84 in |
|
Package Dimensions Metric |
1090 x 500 x 885 mm |
|
Net/Gross Weight |
169.75 / 181.88 lb |
|
Net/Gross Weight Metric |
77 / 82.5 kg |
Efficiency
SEER2: 23
EER2: 12
HSPF2-4: 9.9
COP: 3.15
Cooling Performance
Rated cooling capacity: 34,000 BTU/h.
Minimum/maximum cooling capacity: 9,000–40,000 BTU/h.
Moisture removal: 0.4 L/h.
Standard cooling operating range: -13°F to 122°F (-25°C to 50°C).
Heating Performance
Rated heating capacity at 47°F: 36,000 BTU/h.
Minimum/maximum heating capacity at 47°F: 10,000–40,000 BTU/h.
Rated heating capacity at 17°F: 24,000 BTU/h.
At 5°F, rated heating capacity is 25,200 BTU/h, with a COP of 2. Maximum capacity at 5°F is listed as 25,000 BTU/h.
Standard heating operating range: -13°F to 75°F (-25°C to 24°C).
Electrical Specifications
|
Electrical Specification |
Value |
|
Power Supply |
208/230V, 60Hz, 1Ph |
|
System MCA |
30.5A |
|
Connection Wiring |
14# × 4 |
|
System MOCP |
35A |
|
Compressor RLA |
17A |
|
Outdoor Fan Motor RLA |
1.3A |
|
Outdoor Fan Motor |
150W |
|
Cooling Power Input |
2833W (600–4100W) |
|
Heating Power Input |
3350W (600–3950W) |
Piping & Refrigerant
Five 1/4-inch liquid connections are listed.
Gas connections are listed as four 3/8-inch plus one 1/2-inch.
Maximum piping length for all rooms: 221.4 ft.
Maximum piping length for one indoor unit: 73.8 ft.
Maximum height difference between indoor and outdoor units: 32.8 ft.
Refrigerant precharge: 104.75 oz / 2.97 kg.
Precharge length: 24.6 ft × 5.
Connection method: Quick Connect.
MRCOOL DIY-MULTI6-48HP230D-O Submittal Data
The DIY-MULTI6-48HP230D-O is one of the two six-zone outdoor condensers and uses the larger two-fan outdoor-unit design.

Outdoor Specifications
|
Specification |
Value |
|
Compressor Type |
Rotary |
|
Compressor Model |
KTQ420D1UMU |
|
Refrigerant |
R454B |
|
Refrigerant Oil Charge |
1400 mL |
|
Refrigerant Oil |
VG74 |
|
Maximum Outdoor Airflow |
4502.8 CFM |
|
Outdoor Noise Level |
64 dBA |
|
Dimensions |
37.48 x 16.34 x 52.48 in |
|
Dimensions Metric |
952 x 415 x 1333 mm |
|
Package Dimensions |
43.11 x 19.49 x 58.27 in |
|
Package Dimensions Metric |
1095 x 495 x 1480 mm |
|
Net/Gross Weight |
223.77 / 256.39 lb |
|
Net/Gross Weight Metric |
101.5 / 116.3 kg |
Efficiency
SEER2: 21.8
EER2: 12
HSPF2-4: 10
COP: 3.3
Cooling Performance
Rated cooling capacity: 43,000 BTU/h.
Minimum/maximum cooling capacity: 12,000–52,500 BTU/h.
Moisture removal: 4.3 L/h.
Standard cooling operating range: -13°F to 122°F (-25°C to 50°C).
Heating Performance
Rated heating capacity at 47°F: 48,000 BTU/h.
Minimum/maximum capacity at 47°F: 13,000–54,500 BTU/h.
Rated capacity at 17°F: 35,200 BTU/h.
At 5°F, rated capacity is 37,000 BTU/h, with a COP of 2. Maximum 5°F capacity is also listed as 37,000 BTU/h.
Standard heating operating range: -13°F to 75°F (-25°C to 24°C).
Electrical Specifications
|
Electrical Specification |
Value |
|
Power Supply |
208/230V, 60Hz, 1Ph |
|
System MCA |
40A |
|
Connection Wiring |
14# x 4 |
|
System MOCP |
45A |
|
Compressor RLA |
21.8A |
|
Outdoor Fan Motor RLA |
2.5A |
|
Outdoor Fan Motor |
126W |
|
Cooling Power Input |
3580W (800 - 5680W) |
|
Heating Power Input |
4260W (800 - 5450W) |
Piping & Refrigerant
The sheet lists six 1/4-inch liquid connections.
Gas connections are listed as four 3/8-inch plus two 1/2-inch.
Maximum piping length for all rooms: 221.4 ft.
Maximum piping length for one indoor unit: 73.8 ft.
Maximum indoor/outdoor height difference: 32.8 ft.
Refrigerant precharge: 148.15 oz / 4.2 kg.
Precharge length: 24.6 ft × 6.
Connection method: Quick Connect.
MRCOOL DIY 5th Gen Multi Zone 👉 Shop Now
MRCOOL DIY 5th Gen Multi Zone 👉 Bundle Builder
Mrcool DIY 5th Gen 👉 Installation and owner’s manual
MRCOOL DIY-MULTI6-55HP230D-O Submittal Data
The DIY-MULTI6-55HP230D-O is the largest outdoor condenser in this DIY 5th Generation Multi-Zone group and supports up to six connected zones.

Like the 48K model, it uses the taller two-fan outdoor-unit design.
Outdoor Specifications
|
Specification |
Value |
|
Compressor Type |
Twin-Rotary |
|
Compressor Model |
EKPQ440D1UMUB |
|
Refrigerant |
R454B |
|
Refrigerant Oil Charge |
1460 mL |
|
Refrigerant Oil |
VG75 |
|
Maximum Outdoor Airflow |
4502.8 CFM |
|
Outdoor Noise Level |
64 dBA |
|
Dimensions |
37.48 x 16.34 x 52.48 in |
|
Dimensions Metric |
952 x 415 x 1333 mm |
|
Package Dimensions |
43.11 x 19.49 x 58.27 in |
|
Package Dimensions Metric |
1095 x 495 x 1480 mm |
|
Net/Gross Weight |
245.81 / 276.46 lb |
|
Net/Gross Weight Metric |
111.5 / 125.4 kg |
Efficiency
SEER2: 22
EER2: 12
HSPF2-4: 10.6
COP: 3.25
Cooling Performance
Rated cooling capacity: 47,000 BTU/h.
Minimum/maximum cooling capacity: 19,000–59,000 BTU/h.
Moisture removal: 3.1 L/h.
Standard cooling operating range: -22°F to 122°F (-30°C to 50°C).
Heating Performance
Rated heating capacity at 47°F: 55,000 BTU/h.
Minimum/maximum capacity at 47°F: 20,000–58,500 BTU/h.
Rated capacity at 17°F: 45,000 BTU/h.
At 5°F, rated capacity is 46,000 BTU/h, with a COP of 2. Maximum capacity at 5°F is also listed as 46,000 BTU/h.
Standard heating operating range: -22°F to 75°F (-30°C to 24°C).
Electrical Specifications
|
Electrical Specification |
Value |
|
Power Supply |
208/230V, 60Hz, 1Ph |
|
System MCA |
43A |
|
Connection Wiring |
14# x 4 |
|
System MOCP |
45A |
|
Compressor RLA |
24.1A |
|
Outdoor Fan Motor RLA |
2.5A |
|
Outdoor Fan Motor |
126W |
|
Cooling Power Input |
3917W (1200 - 5800W) |
|
Heating Power Input |
4960W (1200 - 5750W) |
Piping & Refrigerant
The sheet lists six 1/4-inch liquid connections.
Gas connections are listed as four 3/8-inch plus two 1/2-inch.
Maximum piping length for all rooms: 221.40 ft.
Maximum piping length for one indoor unit: 73.80 ft.
Maximum height difference between indoor and outdoor units: 32.8 ft.
Refrigerant precharge: 151.68 oz / 4.3 kg.
Precharge length: 24.6 ft × 6.
Connection method: Quick Connect.
MRCOOL DIY 5th Gen Multi-Zone Quick Comparison
|
Model |
Zones |
Rated Cooling* |
SEER2 |
MCA |
MOCP |
|
DIY-MULTI3-18HP230D-O |
3 |
18,000 BTU/h |
23.9 |
16A |
20A |
|
DIY-MULTI4-27HP230D-O |
4 |
26,000 BTU/h |
23 |
23A |
25A |
|
DIY-MULTI5-36HP230D-O |
5 |
34,000 BTU/h |
23 |
30.5A |
35A |
|
DIY-MULTI6-48HP230D-O |
6 |
43,000 BTU/h |
21.8 |
40A |
45A |
|
DIY-MULTI6-55HP230D-O |
6 |
47,000 BTU/h |
22 |
43A |
45A |
*Important: MRCOOL’s product class/model name and the rated cooling capacity appearing on the submittal sheet are not always identical. For example, the 36K-class model’s submittal lists 34,000 BTU/h rated cooling capacity, while the 48K-class model lists 43,000 BTU/h and the 55K-class lists 47,000 BTU/h. This is why looking at the actual submittal data matters.
Outdoor Unit Installation Clearances
The supplied MRCOOL submittal sheets also provide outdoor-unit clearance diagrams.
They show:
4 inches (100 mm) or more at specified sides.
14 inches (350 mm) or more at the indicated service/airflow area.
20 inches (500 mm) or more when the front and sides of the unit are clear.
The diagrams also state 20 inches (500 mm) or more when any two sides of the left, right and rear of the unit are clear.
Because actual placement conditions can vary, use the clearance diagram for the specific model rather than relying on a single number taken out of context.
MRCOOL DIY 5th Gen Multi Zone 👉 Shop Now
MRCOOL DIY 5th Gen Multi Zone 👉 Bundle Builder
Mrcool DIY 5th Gen 👉 Installation and owner’s manual
Frequently Asked Questions
What refrigerant does the MRCOOL DIY 5th Gen Multi-Zone use?
The five DIY Multi-Zone submittal sheets covered here specify R454B refrigerant.
Are all MRCOOL DIY Multi-Zone condensers the same physical size?
No. The outdoor-unit dimensions vary by model. The 48K and 55K models are substantially taller two-fan condensers, while the smaller models use single-fan designs.
What voltage do these MRCOOL DIY Multi-Zone condensers use?
The supplied submittal sheets specify 208/230V, 60Hz, single-phase power.
What is MCA?
MCA stands for Minimum Circuit Ampacity. It is an electrical value used when determining the minimum ampacity of the branch-circuit conductors serving the equipment.
What is MOCP?
MOCP stands for Maximum Overcurrent Protection. It identifies the maximum permitted overcurrent-protection rating specified for the equipment.
MCA and MOCP should not be treated as interchangeable values.
Can I choose a breaker simply from the condenser’s BTU size?
No. Electrical requirements should be taken from the exact equipment nameplate, applicable documentation and electrical requirements. The submittal information above is useful for planning, but electrical installation should comply with applicable codes and manufacturer instructions.
Does a 55K model mean exactly 55,000 BTU/h of rated cooling?
Not on this submittal. The DIY-MULTI6-55HP230D-O is the 55K-class model, while its supplied submittal lists 47,000 BTU/h rated cooling capacity and 55,000 BTU/h rated heating capacity at 47°F.
How many zones can the DIY Multi-Zone systems support?
This family includes 3-, 4-, 5- and 6-zone outdoor condensers. The number of available connections does not mean every possible indoor-unit combination is approved. Indoor-unit compatibility and system-capacity requirements still need to be checked for the exact configuration.
Are the line connections Quick Connect?
The supplied DIY 5th Gen Multi-Zone submittals list Quick Connect as the connection method.
MRCOOL DIY 5th Gen Multi Zone 👉 Shop Now
MRCOOL DIY 5th Gen Multi Zone 👉 Bundle Builder
Mrcool DIY 5th Gen 👉 Installation and owner’s manual
Need Help Building a MRCOOL DIY Multi-Zone System?
Choosing the outdoor condenser is only one part of designing a Multi-Zone system. Indoor-unit capacities, room loads, compatible air handlers, line-set sizes and lengths, electrical requirements and total connected capacity all need to work together.
MRCOOL DIRECT can help you determine which equipment and accessories are appropriate for your project.
Call MRCOOL DIRECT: 615-553-8118
Hours: Monday–Friday, 8:30 AM–5:00 PM Central Time
MRCOOL DIRECT — You Not Being Cool Is Our Business.